Economical equivalents with quick delivery for replacement of water and wastewater treatment projects.    E-mail: [email protected]

BW RO Membrane TFBW-8040HR

Products

BW RO Membrane TFBW-8040HR

Product No.:TFBW-8040HR

  • Details

General Information

BW RO membrane TFBW-8040HR is developed for reverse osmosis plant managers and operators dealing with brackish water with high rejection rate.
BW RO membrane element provides consistency, high permeate water quality, high performance and productivity, and long service life.

Features & Advantages

  • Provides high-quality permeate water
  • Stable salt rejection rate and high permeate flow rate
  • Optimized design, good resistance to fouling results in long service life
  • High chemical tolerance for cleaning with highly effective cleaning performance
  • Simple and economical element replacement

Applications

  • Industrial pure water
  • Industrial wastewater reuse
  • Slightly contaminated water

Specifications

  • Configuration: Spiral wound element
  • Membrane Polymer: Polyamide thin-film composite

Performance

Element Model

Membrane Active Area
ft2 (m2)

Feed Spacer
mil (mm)

Permeate Flow Rate*
GPD (m3/d)

Stabilized Salt Rejection**

Minimum Salt Rejection

TFBW-8040HR

400 (37.2)

28 (0.712)

10,500 (39.7)

99.7%

99.5%

Standard test conditions:
The above performance is initial (data record after 30 minutes of operation), based on the following conditions:
2,000 ppm NaCl solution
225 psi (15.5 bar) operating pressure
25°C (77°F) operating temperature
15% permeate recovery
7.5-8 pH range
*Permeate flow for individual elements may vary but will be no more than ±15%.
**Stabilized salt rejection is generally achieved within 24-48 hours of continuous use; depending on feed water characteristics and operating conditions.
Element Dimensions
BW RO Membrane Element Dimensions

Length A
inch (mm)

Diameter B
inch (mm)

Permeate tube inner diameter C inch (mm)

40 (1,016)

7.9 (201)

1.125 (28.6)

Operating and Cleaning Limits

Maximum Operating Pressure

600 psi (41 bar)

Maximum Operating Temperature

45°C (113°F)

Maximum Chlorine Concentration

0.1 ppm

pH Range, Continuous

2-11

pH Range, Cleaning

1-13

Maximum Feed SDI (15 mins)

5

Maximum Element Pressure Drop

15 psi (1 bar)

Maximum Feed Flow

17 m3/h

Minimum Ratio of Concentrate to Permeate Flow for Each Element

5:1