Economical equivalents with quick delivery for replacement of water and wastewater treatment projects.    E-mail: [email protected]

RO Membrane TFULP-8040HF

Products

RO Membrane TFULP-8040HF

Product No.:TFULP-8040HF

  • Details

General Information

TaFlux ULP series reverse osmosis membrane elements TFULP-8040HF are developed for energy saving for water treatment in various industries and applications, ideal for reverse osmosis plant managers and operators dealing with low to medium TDS level water with essential pre-treatment.
TaFlux ULP series reverse osmosis membrane element provides consistency, high-quality filtrate, reliable performance, and long service life at a low feed pressure, which saves energy and reduces operation costs.

Features & Advantages

  • High permeability
  • Anti-fouling structure design
  • Good consistency and reliability
  • Economical equivalent element for direct replacement

Applications

  • Municipal drinking water
  • Industrial process water
  • Dual water supply system
  • Pure water preparation plant

Specifications

  • Configuration: Spiral wound element
  • Membrane Polymer: Polyamide thin-film composite

Performance

Element Model

Membrane Active Area

ft2 (m2)

Feed Spacer

mil (mm)

Permeate Flow Rate*

GPD (m3/d)

Stabilized Salt Rejection**

Minimum Salt Rejection

TFULP-8040HF

400 (37.2)

28 (0.712)

12,000 (45.4)

99.2%

99.0%

Standard test conditions:
The above performance is initial (data record after 30 minutes of operation), based on the following conditions:
1,500 ppm NaCl solution
150 psi (10.3 bar) operating pressure
25°C (77°F) operating temperature
15% permeate recovery
7.5-8 pH range
*Permeate flow for individual elements may vary but will be no more than ±15%.
**Stabilized salt rejection is generally achieved within 24-48 hours of continuous use; depending on feed water characteristics and operating conditions.
Element Dimensions
8040 TaFlux ULP Series RO Membrane Element Dimensions

Size

Length L

inch (mm)

Diameter D

inch (mm)

Permeate tube

inner diameter d

inch (mm)

Permeate tube

Extension L1

inch (mm)

8040*

40 (1,016)

7.9 (201)

1.125 (28.6)

/

* Each 8040 seawater RO membrane element supplied with one interconnector (coupler) with four O-rings.
All 8040 seawater membrane elements fit nominal 8.0 inch (203.2 mm) I.D. pressure vessels.
Operating and Cleaning Limits

Maximum Operating Pressure

600 psi (41 bar)

Maximum Operating Temperature

45°C (113°F)

Maximum Chlorine Concentration

0.1 ppm

pH Range, Continuous

2 - 11

pH Range, Cleaning

1 - 13

Maximum Feed SDI (15 mins)

5

Maximum Element Pressure Drop

15 psi (1 bar)

Maximum Feed Flow

17 m3/h

The limits shown above are for general applications. For specific projects, operating at more conservative values may ensure the best performance and longest life of the membrane element.
Post your feedback

The Code:

Wechat Code
Wechat